The TH-3261 Transformer Tester is a multifunctional testing platform offering transformer scanning, LCR testing and DCR/turn-ratio measurement. It supports automated test sequences, selectable output impedance levels and high measurement accuracy suitable for production line testing. With comprehensive data capture and report capabilities, TH-3261 helps manufacturers ensure strict quality control and repeatable test results. Durable construction and simple operator interface speed up testing cycles.

Key Features

  • 20-pin automatic transformer scanning
  • High-precision LCR & DCR measurements
  • Turn ratio and winding diagnostics
  • Selectable output impedance
  • Programmable test sequences
  • Fast scanning for production lines
  • Comprehensive data logging
  • User-friendly operation

Applications

  • Transformer QC in production
  • Turn ratio and DCR testing
  • Batch testing and sorting
  • High-volume transformer lines
  • R&D transformer analysis
  • Quality assurance centers

Technical Specifications

Model TH-3261
Description 20-pin transformer scanning test + LCR test (optional). TH-3261 provides a 10-hour function experience for LCR test. The experience version will automatically turn off after 10 hours of use.
Basic Accuracy (See Operation Manual)
LCRZ 0.05%
DCR, Turn Ratio 0.1%
Calibration Warm-up time > 30 minutes, environment temperature: 23±5°C, single voltage: 0.3Vrms–1Vrms, zeroing after open or short. Length of test cable: 0m.
Frequency of Test Signal
Range 20 Hz – 200 kHz
Resolution 0.5 mHz
Accuracy 0.01%
Output Impedance of Signal Source
Selectable 10 Ω, 30 Ω, 50 Ω, 100 Ω (±1% @ 1 kHz)
Level of AC Test Signal
Normal Level 5mV–10Vrms (Min. resolution: 100 µV, Accuracy: 10% × Set Voltage + 2 mV)
50 µV–100mArms (Min. resolution: 1 µA)
Constant Level 10mV–5Vrms (Min. resolution: 100 µV, Accuracy: 10% × Set Voltage + 2 mV)
100 µV–50mArms (Min. resolution: 1 µA)
DC Bias Voltage Source
Voltage 0V – ±10V (Min. resolution: 0.5 mV, Accuracy: 1% × Set Voltage + 5 mV)
Current 0 mA – ±100 mA (Min. resolution: 0.5 µA)
DC Constant Current Source (Optional)
Optional (Diode P/N Test) 0 – ±120 mA (Min. resolution: 0.5 µA, Accuracy: 1% × Set Voltage + 0.2 mA, Load Open Voltage < 5V)
Optional (TH-3261) 0 – ±1 A (Min. resolution: 0.5 mA, Accuracy: 1% × Set Voltage + 2 mA, Load Open Voltage < 9V)
Transformer Test Parameters
Parameters Turn Ratio, Turns, Phase, L, C, Lk, Q, ACR, DCR, Valance, Pin Short, Diode P/N
LCR Test Parameters
Parameters |Z|, |Y|, C, L, X, B, R, G, D, Q, Θ, DCR, Turn-Ratio, Phase, Lk
Display Ranges
DCR 0.00001 Ω – 99.9999 MΩ
Turn Ratio 1:0.001 – 1000:1